Automatic Vacuum Control Unit

IS9023

Switches the vacuum for you, end after end.
IS9023 Automatic Vacuum Control Unit for enamel rating

About the IS9023 Automatic Vacuum Control Unit

The IS9023 is an optional accessory for the IS9020TMR end adapter. It triggers the IS9021AV vacuum generator automatically, so the vacuum comes on and releases at the right moment in the test cycle without an operator touching a valve.

On a single sample that hardly matters. On a full batch of ends it does: a manual vacuum valve means one repetitive hand movement per sample, and it is the point in the cycle where electrolyte is most likely to be spilled. Automating the switching removes both problems and keeps the operator on the reading rather than on the plumbing. Results still stream into IS1100 Innolytix® with the rest of the line.

Automatic vacuum control unit features

Features of the IS9023 automatic vacuum control unit
Features
Hands off the valve – triggers the vacuum generator automatically, so nobody has to work a manual vacuum valve once per end
Built for batches – removes the repetitive hand movement that slows an operator down when a full batch of ends has to be rated
Spillage protection – controlled switching guards against electrolyte spillage at the moment the end is released
Drops into the existing station – works with the IS9021AV vacuum generator and the IS9020TMR end adapter
Optional by design – add it when throughput or operator fatigue justifies it, without changing the rest of the line

Automatic vacuum control unit specifications

Specifications of the IS9023 automatic vacuum control unit
Function Automatic triggering of the vacuum for the IS9020TMR end adapter
Type Optional accessory
Requires IS9021AV Vacuum Generator
Power supply 110–240 V AC
Used with IS9020TMR End Adapter and the IS810 EnamelPro™ enamel rating gauge
Standard compliance RoHS, WEEE, CE

Frequently Asked Questions

What does the IS9023 automatic vacuum control unit do?

It triggers the vacuum generator automatically during an enamel rating test, so the vacuum that seats and seals each end in the IS9020TMR adapter is switched on and released without an operator opening and closing a manual valve.

Is the IS9023 required or optional?

Optional. The IS9020TMR end adapter and the IS9021AV vacuum generator work with a manual vacuum valve. The IS9023 is the upgrade you add when you want the switching automated.

Why would I automate the vacuum instead of using a manual valve?

Because a manual valve demands one repetitive hand movement per end. Over a full batch that is a real source of operator fatigue and inconsistency, and the release moment is where electrolyte tends to get spilled.

Does the IS9023 replace the IS9021AV vacuum generator?

No. The IS9021AV creates the vacuum; the IS9023 decides when it is applied. You need the generator either way.

Can I add the IS9023 to a station that is already installed?

Yes. It is designed as an add-on to an existing IS9020TMR and IS9021AV setup, so the adapter, gauge and top plates you already have stay in place.

Which enamel rating gauge does it work with?

It belongs to the station built around the IS810 EnamelPro™ enamel rating gauge and the IS9020TMR end adapter.

Complete Enamel Rating Line

Seamless integration with the IS810 EnamelPro™ ecosystem

IS810 EnamelPro™ enamel rating gauge for cans, ends, tubes, capsules and flat sheets
IS810 EnamelPro™ Enamel Rating Gauge

The semi-automatic enamel rating gauge at the heart of the line. Reverse-polarity defect localization and live logging to Innolytix®.

IS9015 can stand fixture for enamel rating 2-piece, 3-piece and aerosol cans
IS9015 Can Stand
Enamel rates 2-piece, 3-piece and aerosol cans.
IS9015-CRW crown cork adapter for enamel rating crown closures
IS9015-CRW Crown Cork Adapter
Covers crown closures and caps.
IS9015XXL large can stand for enamel rating drums, pails and extra-large cans
IS9015XXL Large Can Stand
Enamel rates drums, pails and extra-large cans.
IS9017 tube stand fixture for enamel rating aluminum collapsible tubes
IS9017 Tube Stand
Enamel rates aluminum collapsible tubes.
IS9018 aluminum capsule stand fixture for enamel rating capsules
IS9018 Aluminum Capsule Stand
Handles aluminum capsules and closures.
IS9020TMR end adapter for enamel rating ends, caps, cones, domes and flat sheets
IS9020TMR End Adapter
Enamel rates ends, caps, cones, domes and flat sheets.
IS9025 EOE rivet adapter for enamel rating the rivet area of easy-open ends
IS9025 EOE Rivet Adapter
Isolates and enamel rates the rivet area of easy-open ends.
IS9030 foil adapter for enamel rating thin and thick aluminum foil
IS9030 Foil Adapter
Enamel rates thin and thick aluminum foil.
IS9031 top plate rack for storing enamel rater top plates
IS9031 Top Plate Rack
Bench storage for up to five interchangeable top plates.
IS9021 vacuum generator accessory used with the IS9020TMR end adapter
IS9021 Vacuum Generator
Vacuum generator with filter, water separator and easy air-pressure adjustment.
IS9023 automatic vacuum control unit used with the IS9020TMR end adapter
IS9023 Automatic Vacuum Control Unit
Adds automatic vacuum control to speed up repeat testing.
IS9024 electrolyte management system for filling and emptying cans under test
IS9024 Electrolyte Management System
Semi-automatically fills and empties the can under test with electrolyte.
IS9029 light probe for illuminating the inside of cans and tubes during enamel rating
IS9029 Light Probe
Lights the inside of a can or tube so defects are easy to locate.
IS1100 Innolytix® QA data collection software dashboard showing enamel rating results and pass/fail grid
IS1100 Innolytix® QA Analysis Software
Canmaking QA software. Real-time logging, SPC dashboards and traceable quality records.
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.