Tab Verifier

IS240

Compact system for double shell and missing tab detection on the conversion press

Specially developed to minimize expensive downtime

Benefits

  • Easy to work with for minimal downtime
  • Small sensor dimensions for easy mounting
  • Quick calibration, no need to adjust detection tolerances
  • Calibration input for quick start after maintenance stops
  • Works with aluminium and steel ends/tabs — no adjustments needed
  • No need to re-calibrate after a cable change
  • Suitable for line speeds up to 1000 strokes per minute
Innosen Tab Verifier

NEW FEATURE error codes are now stored for 24 hours for easier tracking of production faults.

IS240 Tab Verifier Sensor

Easy to Install

For each lane, two sensors are installed at the infeed and two at the outfeed of the press, with two electronic cards fitted into the controller. Transmitter sensors are fitted above the conveyor belt and receivers below.  Shells should pass approximately 5mm (0.2”) above the receiver sensors.

R

Quick Calibration

Both a global and a local re-calibration inputs are available. The local input starts calibration only on the selected sensor, while the global input works for the entire system. These inputs give the possibility of using the line control system or an external switch to decide when to initiate calibration.

}

Compact Design

The IS240 sensors have been specially engineered with short and narrow casing for easy fitting into the available space on a typical press (see illustration opposite). The control box with its easy to read signalling system is similarly compact for convenient mounting.

m

Modular System

The IS240 Tab Verifier is a modular system allowing inspection on up to four lanes with one controller. For each shell, the system gives a good and/or bad output signal. Error checks are performed continuously and if any system fault is found, the warning output is activated. Plug-in modules on the controller allow operators to quickly re-route inputs while a fault is being diagnosed, which helps to keep unplanned downtime to a minimum.

Offices

Spain
Gran Via de Lluís Companys, 168- 1 – 2
08330 Premià de Mar (Barcelona)
Spain
Main Multilanguage Tel:
+34 937 549 526
Alternative Direct Tel:
Français: +33 1 76 64 12 87
English: +44 1905 887845
Fax: +34 937 549 687

Hong Kong
11th Floor Dah Sing Life Building
99 Des Voeux Road Central
Hong Kong
Tel: +852 2127 0699

Philippines
808 Citystate Centre Building
709 Shaw Boulevard
1600 Pasig City
Philippines
Tel: +63 2 696 6965
Fax: +63 2 696 6159

Share This